•Power supply:

85-255 V AC / 120-255 V DC / 11,4-40 V DC / 11,4-28V AC

•Ambient temperature: -30 °C to +70 °C

•Medium temperature: -30 °C to +100 °C

•Pressure: 0.7 - 1.1 bar

•Measuring range: 0.6 to 60 m for solids

•Outputs: 4-20 mA, relay, RS485, HART

•Protection: IP 67,

ATEX II 1/2 D IP 65 T130°C

•3/4-wire compact transmitter

•Non-contact level metering

•Narrow 5° beam angle

•Fully temperature compensated

•Excellent signal processing via QUEST+ software

•PP, PVDF, PTFE, stainless steel or foam faced transducers

•Optional field indicator and plug-in programmer/display

•Plastic or aluminium housing

•[ HART ]

•Secondary lightning protection

•HART, RS 485

•Power relay output

•Dust Ex version

•Almost any free flowing solids

•Level, volume or weight calculation and display

•Reliable measurement in challenging applications such as dusting during filling