•Power supply: 10-36V DC
•Ambient temperature: -25 °C to +70 °C
•Medium temperature: -25 °C to +125 °C
•Pressure: 0.1-400 bar, -1 bar
•Outputs: 4-20 mA, HART
•Process connection: 1/2', 1', 11/2' process connection or hygienic fitting
•Protection: IP 65
•Approvals: ATEX II 1 G EEx ia IIC T6...T4
•Two-wire compact transmitter
•Stainless steel diaphragm
•Measuring range: 0.1-400 bar, -1 bar
•Scalable analogue output
•Programmable damping
•Level and pressure management
•Secondary lightning protection
•High overload capability
•High accuracy <0.25%
•Wide temperature ranges
•HART communication
•Explosion-proof models
•Most liquids and masses in tanks and vessels
•Chemicals with dense vapour or gas layers above the surface
•Foaming liquids
•Viscous or corrosive materials